Hero background
Tunnel Fire & Blast Containment Walls

Tunnel Fire & Blast Containment Walls

Background Pattern
Why Tunnel Fire and Blast Protection Matters

Why Tunnel Fire and Blast Protection Matters

Tunnels are high-risk environments where fire, smoke, and pressure escalate in seconds. Conventional concrete isn’t built to withstand these extremes; it spalls and weakens, increasing the risk of structural collapse and blocking vital evacuation routes. Our certified fire and blast protection systems are engineered to perform under extreme conditions, ensuring compliance, structural integrity, and life safety.

Without engineered containment solutions:
Fire and blast forces can spread rapidly across tunnel spans, putting lives and infrastructure at risk.
Concrete linings spall and crack under extreme thermal or pressure loading, exposing reinforcement and compromising structural stability
Toxic gases, radiant heat, and debris can block evacuation routes and severely limit rescue operations.

What Is Tunnel Fire and Blast Containment Wall

A SECURA tunnel containment wall is an engineered composite system designed to withstand severe fire and explosion scenarios, protecting tunnel structures and maintaining structural integrity and safety under extreme conditions.

Fire Resistance

Fire Resistance

Designed to withstand severe tunnel fire curves while maintaining structural integrity.

Blast Protection

Blast Protection

Resists blast overpressure to protect tunnel structures and critical infrastructure.

Thermal Shock Stability

Thermal Shock Stability

Handles rapid temperature spikes and intense radiant heat without loss of performance.

Impact & Debris Resistance

Impact & Debris Resistance

Maintains strength against debris and mechanical loads following fire or blast events.

Smoke & Gas Isolation

Smoke & Gas Isolation

Helps contain smoke and hazardous gases to support safer evacuation routes.

Background Pattern

How the System Protects Your Tunnel

Invicta ANARA integrates three connected capabilities — research and development, certified manufacturing, and technical installation — that work to reduce the risk of compatibility issues across the project life cycle. Panels are designed, tested, and installed to a unified quality standard, enabling full traceability from material selection through to on-site performance. All systems are engineered to meet EN 1363, RABT, HCinc, and project-specific fire curve requirements.

Advanced composite panels withstand extreme heat, limiting structural damage and maintaining tunnel stability during hydrocarbon and rapid-rise fire events.

Engineered systems absorb blast forces and pressure waves, protecting critical tunnel infrastructure and reducing structural risk.

Robust containment walls control falling debris after incidents, reducing hazards and supporting safer recovery operations.

Containment systems limit the spread of smoke and hazardous gases, supporting safer evacuation and emergency response.

Modular designs enable efficient installation and integration into both new-build and existing tunnel structures.

How the System Protects Your Tunnel

Performance & Technical Specifications

Fire & Thermal  Protection

Fire & Thermal Protection

EI 120–240 min fire resistance (standard & high-heat variants).

Compatible with HC, RWS, and tunnel fire curves.

Prevents concrete spalling and protects steel reinforcement under extreme heat.

Smoke & Gas  Containment

Smoke & Gas Containment

Fully sealed system blocks smoke, toxic gases, and hot fire-gases.

Enables safer evacuation and rescue paths.

No hazardous post-event debris or collapse.

Blast & Impact  Resistance

Blast & Impact Resistance

Engineered to withstand high overpressure events.

Maintains structural integrity after combined fire + blast scenarios.

No hazardous post-event debris or collapse.

Materials & Construction

Materials & Construction

Non-combustible, moisture- and corrosion-resistant composite system.

Lightweight vs concrete; fast installation and easier maintenance.

Modular panels fit new builds, retrofits, and complex tunnel geometries.

Advantages Over ConventionalTunnel Protection Methods

Traditional Methods

Concrete or plain-lining risk of spalling, reinforcement failure, structural collapse under fire/heat.

Spray-applied fireproofing / fire boards / mortars may require frequent maintenance, have limited durability, may degrade upon moisture or impact

Passive fire barriers only (fire partitions, boards) limited or no blast, impact, debris, or smoke/gas protection.

Heavy & bulky steel/concrete barriers are difficult, high-cost and have long downtime for retrofit/repair.

SECURA Tunnel Wall Benefits

The composite barrier prevents spalling, maintains integrity, protects reinforcement & structure under extreme fire or blast.

Durable, moisture-resistant, corrosion-proof composite system — long lifecycle, low maintenance, high resilience.

Multi-hazard protection (fire, blast, impact, smoke/gas, thermal, acoustic), enabling comprehensive risk mitigation.

Lightweight modular panels — faster installation, retrofit friendly, minimal disruption to tunnel operations.

Sectors We Serve

Our solutions are designed for sectors where infrastructure reliability, safety, and long-term performance are critical.

Energy & Utilities

Energy & Utilities

Pattern

Energy & Utilities

  • Power & Grid Infrastructure
  • Energy & Process Facilities
  • Onshore & Offshore Assets
  • Renewable Energy Infrastructure
Industrial

Industrial

Pattern

Industrial

  • Chemical & Process Plants
  • Manufacturing & Heavy Industry
  • Hazardous Material storage facilities
  • Automotive & Industrial Campuses
Transportation

Transportation

Pattern

Transportation

  • Airports & Aviation Facilities
  • Metro, Rail & Mass Transit Systems
  • Roads, Highways & Vehicular Tunnels
  • Ports, Shipyards & Marine Transport Infrastructure
Defence

Defence

Pattern

Defence

  • Defence & Command Facilities
  • Critical National Infrastructure (CNI)
  • Secure & Hardened Assets
  • Border, Coastal & Strategic Installations
Infrastructure

Infrastructure

Pattern

Infrastructure

  • Data Centres & Digital Infrastructure
  • Public Venues & Stadia
  • Cultural & Institutional Buildings
  • Government & Diplomatic Facilities
Commercial/Mixed-Use

Commercial/Mixed-Use

Pattern

Commercial/Mixed-Use

  • Hospitality & Leisure
  • Financial & Commercial Buildings
  • Mixed-Use Landmark Developments

Certification

SECURA’s solutions meet or exceed leading international standards.

EN 1363 / EN 1364 /  EN 13501

EN 1363 / EN 1364 / EN 13501

European standards governing fire resistance testing and classification for building elements

BS 476 Part 20–24

BS 476 Part 20–24

British Standard for fire testing of building materialFire resistance of elements (walls, floors, ceilings, and fire doors etc

NFPA 502 / NFPA 251

NFPA 502 / NFPA 251

NFPA 502: Standard for Road Tunnels, Bridges, and Other Limited Access Highway

CTA Background

Ready to Enhance Tunnel Protection?

Partner with our experts to design and implement reliable fire and blast containment solutions.